Refine Your Search

Topic

Search Results

Standard

GROUND ELECTRICAL POWER UNIT, TRANSPORTABLE 115/200 VOLT AC (NOMINAL) 400 HERTZ, 3-PHASE 4-WIRE (GROUNDED NEUTRAL) Y-CONNECTED SYSTEM

1991-05-01
HISTORICAL
ARP1148A
This Recommended Practice outlines the electrical performance characteristics for a continuous duty, diesel or gasoline engine driven brushless alternator unit for supplying 400-Hertz electrical power to commercial transport aircraft. It is intended to assist the airlines in standardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations. The combination of the equipment specified herein and the interconnecting cables(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704 requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

GROUND ELECTRICAL POWER UNIT, TRANSPORTABLE 115/200 VOLT AC (NOMINAL) 400 HERTZ, 3-PHASE 4-WIRE (GROUNDED NEUTRAL) Y-CONNECTED SYSTEM

1970-02-01
HISTORICAL
ARP1148
This Recommended Practice outlines the general requirements for a transportable self-contained, continuous duty, diesel engine driven brushless alternator unit for supplying 400-Hertz electrical power to high performance commercial transport aircraft. It is intended to assist the airlines in standardardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications by the purchaser. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations at airports throughout the world. The combination of the equipment specified herein and the interconnecting cable(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704A requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

GROUND EQUIPMENT - 400 HERTZ GROUND POWER PERFORMANCE REQUIREMENTS

1996-06-01
HISTORICAL
ARP5015
This SAE Aerospace Recommended Practice (ARP) covers the requirements for ground power equipment that supplies 115/200 V, 3-phase, 400 Hz output capable of powering aircraft type loads requiring MIL-STD-704E/DFS-400 quality power. All forms of ground power including mobile and fixed systems are addressed by this document. High voltage (270 V DC) systems are not included in this specification.
Standard

Ground Electrical Power Unit, Transportable 115/200 Volt AC (Nominal) 400 Hertz, 3-Phase 4-Wire (Grounded Neutral) Y-Connected System

2013-10-22
CURRENT
ARP1148B
This Recommended Practice outlines the electrical performance characteristics for a continuous duty, diesel or gasoline engine driven brushless alternator unit for supplying 400-Hertz electrical power to commercial transport aircraft. It is intended to assist the airlines in standardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations. The combination of the equipment specified herein and the interconnecting cables(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704 requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

Ground Equipment - 400 Hertz Ground Power Performance Requirements

2011-01-14
HISTORICAL
ARP5015A
This SAE Aerospace Recommended Practice (ARP) covers the requirements for ground power equipment that supplies 115/200 V, 3-phase, 400 Hz output capable of powering aircraft type loads requiring MIL-STD-704E/DFS-400 quality power. All forms of ground power including mobile and fixed systems are addressed by this document. High voltage (270 V DC) systems are not included in this specification.
Standard

Ground Support Equipment Electrical Systems

2018-09-27
CURRENT
AIR1336B
This SAE Aerospace Information Report (AIR) considers the following major areas: 1 major components and their ratings; 2 selection criteria for optimum design balance for electrical systems; 3 effects of operating conditions and environment on both maintenance and life of components; 4 trouble signals - their diagnosis and cure.
Standard

Ground Support Equipment Hydraulic Systems, Design and Installation, Recommended Practices for

2022-12-16
CURRENT
ARP4943A
This SAE Aerospace Recommended Practice (ARP) covers the design and installation requirements for hydraulic systems (up to 8000 psig [56 MPa]) for ground support equipment (GSE). This ARP is derived from AS5440, which provides hydraulic system requirements for aircraft. The recommendations herein are primarily intended for GSE that exchange hydraulic fluid with the aircraft, such as hydraulic service carts, rather than GSE with non-interfacing hydraulic systems. The GSE may be mobile, portable, or stationary.
Standard

MAINTENANCE OF BATTERIES AND BATTERY CHARGING AND SERVICING FACILITIES

1992-06-10
HISTORICAL
AIR1898
This SAE Aerospace Information Report (AIR) covers, and is restricted to, hands-on servicing/maintenance of industrial lead acid batteries used solely for motive power and exclusively for ground support equipment (GSE). It does not address or pertain to automotive-type SLI (starting-lighting-ignition) batteries or any other types of batteries (such as nickel-cadmium, zinc, or lithium batteries) which may be on-board airport GSE for either motive power or auxiliary uses. Similarly, the battery servicing and charging facilities described herein are those intended exclusively for industrial lead acid batteries.
Standard

Maintenance of Batteries and Battery Charging and Servicing Facilities

2020-09-23
CURRENT
AIR1898A
This SAE Aerospace Information Report (AIR) covers, and is restricted to, hands-on servicing/ maintenance of industrial lead acid batteries used solely for motive power and exclusively for ground support equipment (GSE). It does not address or pertain to automotive-type SLI (starting-lighting-ignition) batteries or any other types of batteries (such as nickel-cadmium, zinc, or lithium batteries) which may be on-board airport GSE for either motive power or auxiliary uses. Similarly, the battery servicing and charging facilities described herein are those intended exclusively for industrial lead acid batteries.
Standard

Maintenance of Ground Support Equipment

2020-09-23
CURRENT
AIR4286
The following are suggested policies, procedures, and practices required to maintain mobile and fixed ground support equipment at airport passenger and cargo terminals. The principal purpose for ground support equipment maintenance is to provide the owner/user with safe, serviceable equipment, in good appearance, at minimal cost, and with minimum downtime. Maintenance programs initiated on ground support equipment must also conform to regulations controlling airport operations. This document has been divided into three sections corresponding to the three stages of equipment life; acquisition, maintenance, and disposal.
Standard

Method of Evaluating Pneumatic Ground Power Units

2003-11-21
HISTORICAL
AIR4545
This SAE Aerospace Information Report (AIR) covers, and is restricted to, the behavior of air under conditions of critical and subcritical flow at temperatures less than 500 °F.
Standard

Method of Testing Pre-Conditioned Air Equipment

2021-04-08
CURRENT
ARP5374B
This SAE Aerospace Recommended Practice (ARP) applies to Point-Of-Use, Central and Mobile Pre-Conditioned Air Equipment. It does not apply to aircraft mounted equipment.
Standard

Method of Testing Pre-Conditioned Air Equipment

2008-04-15
HISTORICAL
ARP5374A
This SAE Aerospace Recommended Practice (ARP) applies to Point-Of-Use, Central and Mobile Pre-Conditioned Air Equipment. It does not apply to aircraft mounted equipment.
Standard

SELECTION CRITERIA FOR RECIPROCATING PRIME MOVERS

1989-10-01
HISTORICAL
ARP1052
This Recommended Practice covers the following categories: a Basic engine rating (requirements for) - (Para. 3) b Suggested minimum conditions for selection - (Para. 4) c Recommended horsepower rating reductions - (Para. 5) d Special considerations - (Para. 6) e Recommended safety devices - (Para. 7) f Recommended minimum instrumentation - (Para. 8) g Recommended selection support data - (Para. 9) h Recommended usage of ARP - (Para. 10)